In a use case like this you're sticking a hundred cells in parallel and [dis]charging them at a fraction of C. This makes the variances in capacity and resistance nearly meaningless. All the cells in a block will safely track the same voltage, and you can easily put a protection circuit on each block to keep that voltage in spec.